- Dry Block – for Temperature Calibration – TA-1200P
- Calibrators
- Temperature
- Dry Block Calibrators
- Solid Insert
- Dry Block - for Temperature Calibration - TA-1200P
Dry Block – for Temperature Calibration – TA-1200P
The TA-1200P Thermocouple Furnace performs functions that would require three different types of instruments: a furnace, standard thermometer and electronic calibrator measuring signals generated by RTDs, thermocouples, thermoswitches and mA generating sources. Besides these functions it has HART® Communication Protocol, data logger mode, Ethernet and USB interface. -Generates temperatures from 50 ºC up to 1200 ºC with a resolution of 0.1 ºC. -Allows the use of a black body insert for the calibration of infrared pyrometers. -Using the internal reference, accuracy of up to ±2.20 ºC. -Using an external thermometer such as Presys Super Thermometer ST-501, accuracy of up to ±0.75 ºC. -Stability of ±0.1 ºC. -Uniformity of ±0.2 ºC. -Input for RTD, thermocouples and thermoswitches. -Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters. -External reference thermometer is optional. -Complete automatic calibration without the use of a computer. -Advanced Documenting capabilities: connection with computer and ISOPLAN calibration software. -Portable, compact, with carrying case and interchangeable inserts.
The TA-1200P Thermocouple Furnace performs functions that would require three different types of instruments: a furnace, standard thermometer and electronic calibrator measuring signals generated by RTDs, thermocouples, thermoswitches and mA generating sources. Besides these functions it has HART® Communication Protocol, data logger mode, Ethernet and USB interface.
-Generates temperatures from 50 ºC up to 1200 ºC with a resolution of 0.1 ºC.
-Allows the use of a black body insert for the calibration of infrared pyrometers.
-Using the internal reference, accuracy of up to ±2.20 ºC.
-Using an external thermometer such as Presys Super Thermometer ST-501, accuracy of up to ±0.75 ºC.
-Stability of ±0.1 ºC.
-Uniformity of ±0.2 ºC.
-Input for RTD, thermocouples and thermoswitches.
-Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.
-External reference thermometer is optional.
-Complete automatic calibration without the use of a computer.
-Advanced Documenting capabilities: connection with computer and ISOPLAN calibration software.
-Portable, compact, with carrying case and interchangeable inserts.