- Home
- DT-8867H/8868/8868H/8869/8869H
- Test And Measuring Instruments
- Temperature
- Infrared Thermometers
- DT-8867H/8868/8868H/8869/8869H
DT-8867H/8868/8868H/8869/8869H
8867H/8868/8868H/8869/8869H Series provide much faster, easier and accurate readings for most surface temperature measurements with Dual laser pointers. Two laser points converge to a single spot when the unit is at the optimal distance from the object being measured. -150ms faster sampling time with 1% accuracy -High 50 to 1 distance to target ratio measures smaller surface areas at greater distances -Widest temperature range -Unique flat surface, modern housing design -Built-in dual laser pointers for accurate targeting -Automatic Data Hold & Trigger Lock -Max, Min, DIF, AVG record -High and low temp. alarm -Emissivity Digitally adjustable from 0.10 to 1.0 -USB interface -Compatible with all standard connector Type K thermocouples. Size (H x W x D): 204mm x 155mm x 52mm Weight: 320g
8867H/8868/8868H/8869/8869H Series provide much faster, easier and accurate readings for most surface temperature measurements with Dual laser pointers. Two laser points converge to a single spot when the unit is at the optimal distance from the object being measured.
-150ms faster sampling time with 1% accuracy
-High 50 to 1 distance to target ratio measures smaller surface areas at greater distances
-Widest temperature range
-Unique flat surface, modern housing design
-Built-in dual laser pointers for accurate targeting
-Automatic Data Hold & Trigger Lock
-Max, Min, DIF, AVG record
-High and low temp. alarm
-Emissivity Digitally adjustable from 0.10 to 1.0
-USB interface
-Compatible with all standard connector Type K thermocouples.
Size (H x W x D): 204mm x 155mm x 52mm
Weight: 320g
| Features |
| User selectable ºC or ºF |
| Dual Laser targeting |
| Automatic Data Hold |
| Auto Power Off |
| White Backlit LCD Display |
| Overrange indication |
| High Temperature |
| Max, Min, DIF, AVG record |
| High / low alarm, Trigger lock |
| Adjustable emissivity |
| Reading memory (8868/8869/8868H/8869H) |
| Type K input |
| USB interface |
| Specifications | DT-8867H | DT-8868 | DT-8869 | DT-8868H | DT-8869H |
| IR Temp. Range | -50ºC to 1650ºC/
-58ºF to 3002ºF |
-50ºC to 1200ºC/
-58ºF to 2192ºF |
-50ºC to 1600ºC/ -58ºF to 2912ºF | -50ºC to 1850ºC/ -58ºF to 3362ºF | -50ºC to 2200ºC/ -58ºF to 3992ºF |
| Response Time | Less than 150ms | Less than 150ms | Less than 150ms | Less than 150ms | Less than 150ms |
| Resolution | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º |
| Basic Accuracy (IR) | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading |
| Optical Resolution | 30:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size |
| Emissivity | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 |
| Type K Temp. Range | -50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
| Basic Accuracy (TK) | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading |
| Readings memories | 99 | 99 | 99 | 99 |