TA Temperature Calibrators – TA-350PL – TA-650PL

The New TA Advanced Temperature Calibrators are the result of our 20 years experience in dry block calibrators manufacturing. -The calibration of your sensors has never been so easy with the TA user-friendly interface on its large touch screen. You can get now a calibration test report at your finger tip without installing any specific software. -The TA makes it all! It has an internal temperature standard, a calibrator for your DUT (Device Under test) measurements and an internal powerful processor to control the automatic cycling and generates the calibration reports. -The TA dry block will also connect easily to your metrology or CMMS (Computerized Maintenance Management System) applications as it has an open and documented protocol as well as different modern way to communicate through an Ethernet, Wi-Fi or USB interface. -TA series are available for a wide temperature range from -60 °C to 1200 °C covering most of your industrial temperature calibration needs and they are conform to EURAMET/cg-13/V03, EA Guidelines.

Referance High Temperature Furnace TA-1200PLAB

The TA-1200PLAB is a deep immersion high temperature furnace, offering the best-in-class uniformity and stability, that will reduce drastically the uncertainties of your thermocouples calibrations. -Operating Range: 50 to 1200 ºC. -Radial Homogeneity: ±0.10 ºC @ 1100 ºC. -Axial Homogeneity: ±0.20 ºC @ 1100 ºC. -Stability: ± 0.10 ºC @ 1100 ºC. -Resolution: 0.01 ºC. -Immersion: 300 mm. -Measurement Zone: 100 mm. -Noise reduction design of the heater core. -External reference thermocouple input. -Deviation Function for TC test sensors. -Ethernet, Wireless, USB, TCP/IP - Built-in Web Server. -Build in VNC for remote access and technical support. -Meets the AMS2750E recommandations. -Easy LabView interface with the WebAp.

Portable Dry Block and Micro-Bath TE-25NL TE-35NL TE-45NL

-Multifunction 4 in 1 (dry block, micro-bath, black body and surface) -Inputs for measuring Device Under Test -Portable and optimized for onsite calibration -Best value for money -Resolution of 0.01 °C. -Stability ± 0.02 °C. -Input for RTD, thermocouples and thermostats, etc.. -Internal regulated 24 Vdc power supply and 4-20mA input for 2-wire transmitters. -Complete automatic calibration with or without the use of the a computer (auto-cycling). -Documenting capabilities: connection with computer and ISOPLAN® calibration software. -Remote Control via Bluetooth and Android application.

Multifunction Temperature Calibrator T-650PH

-Generates temperatures from ambient to 650 °C. -Dry Block and Black Body Inserts. -Horizontal mounting, facilitates infrared thermometer calibration.

Multifunction Temperature Calibrator T-1200PH

-Generates temperatures from 50 °C to 1200 °C. -Dry Block and Black Body Inserts. -Horizontal mounting, facilitates infrared thermometer calibration.

Multifunction Temperature Calibrator – T-35NH

-Generates temperatures from -35 °C to 140 °C. -Dry Block and Black Body Inserts. -Horizontal mounting, facilitates infrared thermometer calibration.

Dry Blocks for Temperature Calibration – TA-25N / TA-35N / TA-50N

The TA-25N, TA-35N and TA-50N Dry Block Calibrators perform functions that would require three different types of instruments: dry block calibrator, standard thermometer and calibrator for TCs, RTDs, mA, mV, ohms and thermoswitches. Besides these functions they have HART® Communication Protocol, data logger mode, Ethernet and USB interface. -TA-50N generates the coolest temperature provided by a dry block. It reaches –50 ºC in an ambient temperature of 23 ºC, with no need of well insulator and no need to place it in a low temperature room. -Optional temperature measurement and control by external probe with Callendar-Van Dusen coefficients. -Accuracy of up to ±0.1 ºC with the internal reference, ±0.07 ºC with the external probe or ±0.05 ºC using an external thermometer such as Presys Super Thermometer ST-501. -Resolution of 0.01 ºC. -Stability of ±0.02 ºC for the entire range of temperature. -Input for RTD, thermocouples and thermoswitches. -Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters. -External reference thermometer not necessary. -Completely automatic calibration with or without the use of a computer. -Documenting capabilities: connection with computer and ISOPLAN-5 calibration software. -Portable, compact, with carrying case and interchangeable inserts.

Dry Blocks for Temperature Calibration – T-25N T-35N T-50N

The T-25N, T-35N and T-50N models control temperature over an insert in order to calibrate thermocouples, thermoresistances, glass thermometers, thermoswitches,etc. Besides providing high accuracy temperature values, they also allow the measurement of signals generated by the thermocouples, thermoresistances and thermoswitches, which are being calibrated. This is possible due to an embedded calibrator specific for these types of signal, including 4-20 mA. They incorporate the function of dry block, standard thermometer and calibrator for RTD and TC sensors, besides mA reading. They present a wide range of programming resources, allowing them to perform automatic calibration of the sensors. In this case, the sensor is placed in the insert and its electrical terminals are connected to the embedded calibrator, the operator defines the calibration points and the number of repetitions, then the process is started so that all the sequence is automatically accomplished. Another way of performing automatic documented calibrations is by means of ISOPLAN-5 calibration software for PC/Windows™ which uses the RS-232 serial port to connect PC to the dry block. With ISOPLAN-5 it is possible to register sensors and instruments of the factory, generate work orders, create and print calibration certificates and reports, that is, it brings all the advantages of computer data management to the calibration environment.

Dry Blocks for – Temperature Calibration – T-350P/T-650P

The T-350P and T-650P Dry Block Calibrators perform functions that would require three different types: a dry block, standard thermometer and electronic calibrator measuring signals generated by RTDs, thermocouples, thermoswitches and mA generating sources. -The T-350P and T-650P model generate from ambient temperature to 350 °C and 650 °C respectively with a resolution of 0.01 °C. -Using a external thermometer such as Presys Super thermometer PT-511, the accuracy up to ± 0.05 °C. -Stability of ± 0.05 °C. -Input for RTD, thermocouples and thermoswitches. -Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters. -External reference thermometer not necessary. -Completely automatic calibration with or without the use of a computer. -Documenting capabilities: connection with computer and ISOPLAN calibration software. -Portable, compact, with carrying case and interchangeable inserts.

Dry Blocks – for Temperature Calibration – TA-350P TA-650P

The TA-350P and TA-650P Dry Block Calibrators perform functions that would require three different types of instruments: a dry block, standard thermometer and electronic calibrator measuring signals generated by RTDs, thermocouples, thermoswitches and mA generating sources. Besides these functions they have HART® Communication Protocol, data logger mode, Ethernet and USB interface. -The TA-350P and TA-650P models generate from ambient temperature to 350 ºC and 650 ºC, respectively, with a resolution of 0.01 ºC. -Optional temperature measurement and control by external probe with Callendar-Van Dusen coefficients. -Using the internal reference, accuracy of up to ±(0.1 ºC + 0.1 % of reading). -Using the external probe, accuracy of up to ±0.07 °C for TA-350P and ±0.10 °C for TA-650P. -Using an external thermometer such as Presys Super Thermometer ST-501, accuracy of up to ±0.05 ºC. -Stability of ±0.05 ºC. -Uniformity of ±0.05 ºC. -Input for RTD, thermocouples and thermoswitches. -Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters. -External reference thermometer not necessary. -Completely automatic calibration with or without the use of a computer. -Documenting capabilities: connection with computer and ISOPLAN calibration software. -Portable, compact, with carrying case and interchangeable inserts.

Dry Block TA-60NL

-All Advanced Functions and Communication features of our Advanced Series. -Process the ITS-90 and Callendar-Van Dusen coefficients. -35 mm diameter and 160 mm length Solid insert or Liquid Bath insert. -Very Silent operation with regulated ventilation for use in laboratory.

Dry Block Calibrators (high temperatures) –
TE-350P TE-650P TE-1200P

The TE-350P, TE-650P and TE-1200P models control temperature over an insert in order to calibrate thermocouples, thermoresistances, glass thermometers, thermoswitches etc. Besides that, the TE-1200P model may work as a black body source. Besides providing high accuracy temperature values, they also allow the measurement of signals generated by the thermocouples, thermoresistances and thermoswitches, which are being calibrated. This possible due to an embedded calibrator specific for these types of signals, including 4-20 mA. They incorporate the function of dry block, standard thermometer and calibrator for RTD and TC sensors, besides mA reading. They present a wide range of programming resources, allowing them to perform automatic calibration of the sensors, with or without the use of a computer. With ISOPLAN® it is possible to register sensors and instruments of the factory, generate work orders, create and print calibration certificates and reports, i.e., it brings all the advantages of computer data management to the calibration environment.

  • 1
  • 2
SWITCH THE LANGUAGE
AZTECH Instruments

The devices are designed to help buyers better understand its production processes and increase the efficiency. Clients are able to level up their product quality and output quantity.

Cart